FEATURE STATE: Kubernetes v1.9
alpha
This feature is currently in a alpha state, meaning:
As of Kubernetes 1.9, persistent volume claims (PVCs) that are in active use by a pod can be protected from pre-mature removal.
PVCProtection
alpha features enabled.The example below uses a GCE PD StorageClass
, however, similar steps can be performed for any volume type.
Create a StorageClass
for convenient storage provisioning:
apiVersion: storage.k8s.io/v1
kind: StorageClass
metadata:
name: slow
provisioner: kubernetes.io/gce-pd
parameters:
type: pd-standard
Verification scenarios follow below.
kind: PersistentVolumeClaim
apiVersion: v1
metadata:
name: slzc
spec:
accessModes:
- ReadWriteOnce
storageClassName: slow
resources:
requests:
storage: 3.7Gi
kubernetes.io/pvc-protection
set:
$ kubectl describe pvc slzc
Name: slzc
Namespace: default
StorageClass: slow
Status: Bound
Volume: pvc-bee8c30a-d6a3-11e7-9af0-42010a800002
Labels: <none>
Annotations: pv.kubernetes.io/bind-completed=yes
pv.kubernetes.io/bound-by-controller=yes
volume.beta.kubernetes.io/storage-provisioner=kubernetes.io/gce-pd
Finalizers: [kubernetes.io/pvc-protection]
Capacity: 4Gi
Access Modes: RWO
Events:
Type Reason Age From Message
---- ------ ---- ---- -------
Normal ProvisioningSucceeded 2m persistentvolume-controller Successfully provisioned volume pvc-bee8c30a-d6a3-11e7-9af0-42010a800002 using kubernetes.io/gce-pd
kind: Pod
apiVersion: v1
metadata:
name: app1
spec:
containers:
- name: test-pod
image: k8s.gcr.io/busybox:1.24
command:
- "/bin/sh"
args:
- "-c"
- "date > /mnt/app1.txt; sleep 60 && exit 0 || exit 1"
volumeMounts:
- name: path-pvc
mountPath: "/mnt"
restartPolicy: "Never"
volumes:
- name: path-pvc
persistentVolumeClaim:
claimName: slzc
Running
, i.e. the PVC becomes in active use.Terminating
:Name: slzc
Namespace: default
StorageClass: slow
Status: Terminating (since Fri, 01 Dec 2017 14:47:55 +0000)
Volume: pvc-803a1f4d-d6a6-11e7-9af0-42010a800002
Labels: <none>
Annotations: pv.kubernetes.io/bind-completed=yes
pv.kubernetes.io/bound-by-controller=yes
volume.beta.kubernetes.io/storage-provisioner=kubernetes.io/gce-pd
Finalizers: [kubernetes.io/pvc-protection]
Capacity: 4Gi
Access Modes: RWO
Events:
Type Reason Age From Message
---- ------ ---- ---- -------
Normal ProvisioningSucceeded 52s persistentvolume-controller Successfully provisioned volume pvc-803a1f4d-d6a6-11e7-9af0-42010a800002 using kubernetes.io/gce-pd
Terminated
(either delete the pod or wait until it finishes). Afterwards, check that the PVC is removed.kind: Pod
apiVersion: v1
metadata:
name: app1
spec:
containers:
- name: test-pod
image: k8s.gcr.io/busybox:1.24
command:
- "/bin/sh"
args:
- "-c"
- "date > /mnt/app1.txt; sleep 600 && exit 0 || exit 1"
volumeMounts:
- name: path-pvc
mountPath: "/mnt"
restartPolicy: "Never"
volumes:
- name: path-pvc
persistentVolumeClaim:
claimName: slzc
Running
, i.e. the PVC becomes in active use.Terminating
:Name: slzc
Namespace: default
StorageClass: slow
Status: Terminating (since Fri, 01 Dec 2017 14:47:55 +0000)
Volume: pvc-803a1f4d-d6a6-11e7-9af0-42010a800002
Labels: <none>
Annotations: pv.kubernetes.io/bind-completed=yes
pv.kubernetes.io/bound-by-controller=yes
volume.beta.kubernetes.io/storage-provisioner=kubernetes.io/gce-pd
Finalizers: [kubernetes.io/pvc-protection]
Capacity: 4Gi
Access Modes: RWO
Events:
Type Reason Age From Message
---- ------ ---- ---- -------
Normal ProvisioningSucceeded 52s persistentvolume-controller Successfully provisioned volume pvc-803a1f4d-d6a6-11e7-9af0-42010a800002 using kubernetes.io/gce-pd
kind: Pod
apiVersion: v1
metadata:
name: app2
spec:
containers:
- name: test-pod
image: gcr.io/google_containers/busybox:1.24
command:
- "/bin/sh"
args:
- "-c"
- "date > /mnt/app1.txt; sleep 600 && exit 0 || exit 1"
volumeMounts:
- name: path-pvc
mountPath: "/mnt"
restartPolicy: "Never"
volumes:
- name: path-pvc
persistentVolumeClaim:
claimName: slzc
Warning FailedScheduling 18s (x4 over 21s) default-scheduler persistentvolumeclaim "slzc" is being deleted
Terminated
(either delete the pods or wait until they finish). Afterwards, check that the PVC is removed.